van Vliet-Vroegindeweij, C., Wheeler, F. J., Stecher-Rasmussen, F., Moss, R. and Huiskamp, R. Microdosimetry Model for Boron Neutron Capture Therapy: I. Determination of Microscopic Quantities of Heavy Particles on a Cellular Scale.

Due to the limitations of existing microdosimetry models, a new model called MICOR has been developed to analyze the spatial distribution of microscopic energy deposition for boron neutron capture therapy (BNCT). As in most existing models, the reactions independent of the incident neutron energy such as the boron and the nitrogen capture reactions can be considered. While other models do not include reactions that are dependent on the neutron energy such as the proton recoil reaction, the present model is designed so that the energy deposition resulting from these reactions is included. The model MICOR has been extended to enable the determination of the biological effects of BNCT, which cannot be done with the existing models. The present paper describes the determination of several microscopic quantities such as the number of hits, the energy deposition in the cell nucleus, and the distribution of lineal and specific energy deposition. The companion paper (Radiat. Res. 155, 000–000 2001) deals with the conversion of these microscopic quantities into biological effects. The model is used to analyze the results of a radiobiological experiment performed at the HB11 facility in the HFR in Petten. This analysis shows the value of the model in determining the dose depositions on a cellular scale and the importance of the extension to the energy deposition of the proton recoil.

Corine van Vliet-Vroegindeweij, Floyd Wheeler, Finn Stecher-Rasmussen, Ray Moss, and René Huiskamp "Microdosimetry Model for Boron Neutron Capture Therapy: I. Determination of Microscopic Quantities of Heavy Particles on a Cellular Scale," Radiation Research 155(3), 490-497, (1 March 2001). https://doi.org/10.1667/0033-7587(2001)155[0490:MMFBNC]2.0.CO;2
Received: 18 October 1999; Accepted: 1 September 2000; Published: 1 March 2001